Silabus Training
Pelatihan ENGINEERING IN MINING – POWER SYSTEM PROTECTION
INTRODUCTION
Electrical power system operates at various voltage levels from 415 V to 400 KV or even more. Electrical apparatus used may be enclosed (e.g., motors) or placed in the open (e.g., transmission lines). All such equipment undergo abnormalities in their lifetime due to various reasons. To achieve safety of the system, electrical equipment has to be monitored to protect it and provide human safety under abnormal operating conditions.
This course is designed to help students to gain theoretical and applied understanding of power system protection, Protection schemes for various power system configurations, Fault current calculations, Protection of generators, transformers, transmission lines, bus bars and feeders. After completing this course, students will gain professional knowledge on the emerging issues and challenges in the power system protection field related to increasing penetrations of distributed generation and intelligent, self-healing networks.
WHO SHOULD ATTEND THIS TRAINING?
- Electrical Engineers
- Instrumentation Engineers
- Electricians
- Maintenance Engineers
- Supervisors
- Technicians
- Maintenance technicians
- Plant Engineers
- Design Engineers
- Project and/or Construction Engineer
TRAINING MATERIAL OUTLINE
- PROTECTION FUNDAMENTALS
- Power system protection
- Protection philosophy
- Protection system components
- CALCULATION FAULT CURRENTS
- Possible faults
- Magnitudes of fault currents
- Per unit impedance in fault calculations
- Calculation of short circuit
- Calculations using impedance
- EARTHING AND ITS RELEVANCE TO PROTECTION
- Type of system and earthing fault magnitude
- Effects of electricity on humans
- Electric shock modes of contact
- Earth loop resistance and protection
- PROTECTIVE DEVICES AND COORDINATION
- Protection approach
- Fuses types
- Fuse application
- Digital protection features
- Typical modern relays
- Extended protection
- CIRCUIT BREAKERS
- Purpose of circuit breakers
- Types of circuit breakers
- Battery construction
- INSTRUMENT TRANSFORMER
- Theory of Operation
- Voltage Transformer
- Current Transformer
- CT magnetizing curve
- Polarity
- RELAY TYPES
- Two basic protection types
- Operation of IDMTL relay
- Current setting IDMTL relay
- Time multiplier setting
- Different operating curves
- Intelligent electronic devices
- PROTECTION COORDINATION
- Basic principle
- Time and current coordination
- Characteristics of IDMT relay
- Ideal coordination of setting curves
- FEEDER PROTECTION
- Unit Protection
- Advantages of unit protection
- Feeder protection
- 3 phase over current and earth fault
- Directional protection
- TYPICAL PROTECTION IN COLLIERY
- Ground leakage protection
- Ground leakage sensitivities
- Pilot wire monitor
- Earth fault lockout
- NER monitor
- NEED TO PROTECT BUSBARS
- Protection
- Frame leakage BB protection
- Busbar blocking scheme
- Zone selective interlocking scheme
- Optical sensing
- TRANSFORMER PROTECTION
- Inter Turn and Core faults
- Delta star transformer
- Transformer earth fault current
- Resistance earth neutral
- Earth fault protection
- Buchholz protection
- ELECTRIC MOTORS
- Failure breakup
- Protection needed by AC motors
- Protection of motors
- Most important failure windings
- THERMAL MODE OF MOTORS
- Steady state temperature
- Temperature rise multiple starts
- Effect of unbalanced current
- Hot and cold condition
- Starting problems
- Relay providing protection
- SHORT CIRCUIT PROTECTION
- Earth fault LV
- Earth fault HV- Low resistance earthing
- Earth fault HV- High resistance earthing
- Negative sequence protection
- Temperature based protection
- Other protection
- GENERATOR PROTECTION
- Small and medium sized Industrial generators
- Generators- Electrical fault
- Generators- Mechanical faults
- Earth fault protection
- Overload protection
- Overcurrent protection
- GENERATOR UNBALANCE PROTECTION
- Rotor fault protection
- Change of field distribution
- Field failure
- Out of synchronization
- PRODUCTION MANAGEMENT
- Typical generator protection
- Functions of maintenance
- Issues of maintenance
- Configuration records
VENUE : Yogyakarta (Ibis Styles Hotel/ Ibis Malioboro Hotel/ Jambuluwuk Hotel/ Cavinton Hotel/ Grand Zuri Hotel, dll)
TRAINING DURATION : 4 days
Jadwal Training
72 tanggal tahun 2027, 2026 di Yogyakarta.
2027
Januari 2027
Februari 2027
Maret 2027
April 2027
Mei 2027
Juni 2027
Juli 2027
Agustus 2027
September 2027
Oktober 2027
November 2027
Desember 2027
2026
Januari 2026
Februari 2026
Maret 2026
April 2026
Mei 2026
Juni 2026
Juli 2026
Agustus 2026
September 2026
Oktober 2026
November 2026
Desember 2026
INVESTMENT PRICE/PERSON
- Rp. 8.500.000/person (full fare) or
- Rp. 8.250.000/person (early bird, payment 1 week before training) or
- Rp. 7.950.000/person (if there are 3 persons or more from the same company)
FACILITIES FOR PARTICIPANTS
- Modul Pelatihan
- Sertifikat Pelatihan/Attendance
- Instruktur Qualified
- Notebook & Ballpoint
- T-Shirt
- Goody Bag
- Dokumentasi Pelatihan
- Ruang Pelatihan (Full AC & Multimedia)
- Makan Siang & 2x Coffee Break
Pertanyaan Umum
Apa itu Engineering IN Mining – Power System Protection?
Siapa saja peserta Engineering IN Mining – Power System Protection?
Berapa lama durasi Engineering IN Mining – Power System Protection?
Di kota mana Engineering IN Mining – Power System Protection dilaksanakan?
Berapa biaya Engineering IN Mining – Power System Protection?
Kapan jadwal Engineering IN Mining – Power System Protection berikutnya?
Bagaimana cara mendaftar Engineering IN Mining – Power System Protection?
Masih ada pertanyaan? Hubungi tim kami atau isi formulir pendaftaran.
Training Serupa
- Digital Marketing untuk UMKM – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
- Digital Marketing Berbasis Kecerdasan Buatan (Artificial Intelligence) – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
- Search Engine Optimization (SEO) Specialist – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
- Content Creator – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
- Sosial Media Marketing – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
- Digital Marketing – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
- Image Editor – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
- Operator Desain Senior – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
- Operator Desain Junior – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
- Fotografer Model – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
- Junior Graphic Designer – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
- Digital Content Operator – Sertifikasi BNSPBandung, Jakarta, Yogyakarta
Artikel Terkait
Training Corrosion and Cathodic Protection untuk Memahami Pengendalian Korosi
Training Variable Speed Drives Operation, Protection and Maintenance
Training Variable Frequency Drives Operation, Protection and Maintenance
Training Power Protection Relay System
Training Lightning Protection and Grounding System for Power Plant, Transmission, Distribution and Large Industry
Training Lightning Protection and Grounding System untuk Industri Migas dan Petrokimia